Availability: | |
---|---|
Quantity: | |
FCST-TH-SMC05
FCST
Note:The practical application of this Composite Manhole Chamber, covering many fields such as municipal administration, electric power,electricity, water, road administration,and drainage.
Product Advantages
lStrong corrosion resistance about manhole chamber
lGood resistance to high and low temperature
lEasy installation for this composite manhole chamber
lConvenient transportation and cost reduction
lTelecom Access Manhole Long service life
lFTTx Access Chambers Height adjustable
Product Size
Product Specifications
All products comply with EN124:1994 standards.
Chemical Resistance Performance
Chemicals | Concentrated Sulfuric Acid | Sodium Hydroxide | Sodium Chloride |
Test Conditions | Soaked in the specified solution for 48h | ||
Test results | No obvious corrosion on the surface, qualityloss <1% |
Mechanical Performance
Items | Standard No. | Requirements | Test Results |
Tensile Strength | GB/T1447-2005 | ≥100MPa | 105MPa |
Tensile Modulus | GB/T1447-2005 | ≥10GPa | 11.8GPa |
Bending Strength | GB/T1449-2005 | ≥200MPa | 213MPa |
Flexural Modulus | GB/T1449-2005 | ≥10GPa | 11.3GPa |
Impact Toughness | GB/T1451-2005 | ≥80KJ/㎡ | 90.8KJ/㎡ |
Barr's Hardness | GB/T3854-2005 | ≥50 | 56 |
Chamber Load
Chamber Type | FCST-TH-SMC05 |
Axial Test Load | 100KN |
Lateral Test Load | 40KN |
Thermal Performance
Items | Standard No. | Test Results |
Heat Distortion Temperature | GB/T1634.2-2004 | > 200°C |
Bending Strength | GB/T9979- 2005(-40°C) | 265MPa |
Flexural modulus | GB/T9979- 2005(-40°C) | 1.43x10^(4) MPa |
Bending strength retention rate | GB/T9979- 2005(-40°C) | 124% |
Flexural modulus retention rate | GB/T9979- 2005(-40°C) | 11.16% |
Linear expansion coefficient | B/T2572-205 | 1.66x10^(-5) |
On each side of the telecom manhole, 6 drill holes are reserved at the factory, and there is a hole opener. The size of the drill hole can be adjusted at the construction site according to the actual size of the HDPE Silicon Pipe/HDPE Micro-duct.
Note:The practical application of this Composite Manhole Chamber, covering many fields such as municipal administration, electric power,electricity, water, road administration,and drainage.
Product Advantages
lStrong corrosion resistance about manhole chamber
lGood resistance to high and low temperature
lEasy installation for this composite manhole chamber
lConvenient transportation and cost reduction
lTelecom Access Manhole Long service life
lFTTx Access Chambers Height adjustable
Product Size
Product Specifications
All products comply with EN124:1994 standards.
Chemical Resistance Performance
Chemicals | Concentrated Sulfuric Acid | Sodium Hydroxide | Sodium Chloride |
Test Conditions | Soaked in the specified solution for 48h | ||
Test results | No obvious corrosion on the surface, qualityloss <1% |
Mechanical Performance
Items | Standard No. | Requirements | Test Results |
Tensile Strength | GB/T1447-2005 | ≥100MPa | 105MPa |
Tensile Modulus | GB/T1447-2005 | ≥10GPa | 11.8GPa |
Bending Strength | GB/T1449-2005 | ≥200MPa | 213MPa |
Flexural Modulus | GB/T1449-2005 | ≥10GPa | 11.3GPa |
Impact Toughness | GB/T1451-2005 | ≥80KJ/㎡ | 90.8KJ/㎡ |
Barr's Hardness | GB/T3854-2005 | ≥50 | 56 |
Chamber Load
Chamber Type | FCST-TH-SMC05 |
Axial Test Load | 100KN |
Lateral Test Load | 40KN |
Thermal Performance
Items | Standard No. | Test Results |
Heat Distortion Temperature | GB/T1634.2-2004 | > 200°C |
Bending Strength | GB/T9979- 2005(-40°C) | 265MPa |
Flexural modulus | GB/T9979- 2005(-40°C) | 1.43x10^(4) MPa |
Bending strength retention rate | GB/T9979- 2005(-40°C) | 124% |
Flexural modulus retention rate | GB/T9979- 2005(-40°C) | 11.16% |
Linear expansion coefficient | B/T2572-205 | 1.66x10^(-5) |
On each side of the telecom manhole, 6 drill holes are reserved at the factory, and there is a hole opener. The size of the drill hole can be adjusted at the construction site according to the actual size of the HDPE Silicon Pipe/HDPE Micro-duct.